e0ee37fcc9d76821d8b42fd2cee1274d7e6aa187
Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-26-47.png
| ... | ... | Binary files /dev/null and b/Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-26-47.png differ |
Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-27-15.png
| ... | ... | Binary files /dev/null and b/Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-27-15.png differ |
Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-31-46.png
| ... | ... | Binary files /dev/null and b/Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-31-46.png differ |
Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-32-04.png
| ... | ... | Binary files /dev/null and b/Chip-cn-dat/Vollgo-dat/EV1527-dat/2025-07-08-13-32-04.png differ |
Chip-cn-dat/Vollgo-dat/EV1527-dat/EV1527-dat.md
| ... | ... | @@ -49,6 +49,19 @@ Typically, EV1527-compliant remote controls use the license-free 315MHz ISM band |
| 49 | 49 | |
| 50 | 50 | - [[RF-link-dat]] |
| 51 | 51 | |
| 52 | +## Schematic |
|
| 53 | + |
|
| 54 | + |
|
| 55 | + |
|
| 56 | + |
|
| 57 | +## boards in the market |
|
| 58 | + |
|
| 59 | + |
|
| 60 | + |
|
| 61 | + |
|
| 62 | + |
|
| 63 | + |
|
| 64 | + |
|
| 52 | 65 | ## ref |
| 53 | 66 | |
| 54 | 67 | - [[EV1527]] |
Chip-dat/PIC-dat/PIC-dat.md
| ... | ... | @@ -14,8 +14,12 @@ PIC16F1823 |
| 14 | 14 | |
| 15 | 15 | PIC12F1572 |
| 16 | 16 | |
| 17 | +- [[PIC12-dat]] |
|
| 18 | + |
|
| 17 | 19 | ## Chips |
| 18 | 20 | |
| 21 | + |
|
| 22 | + |
|
| 19 | 23 | - [[PIC16F1933-DAT]] - [[PIC16F72-dat]] |
| 20 | 24 | |
| 21 | 25 |
Chip-dat/farnell-dat/2025-07-08-13-30-49.png
| ... | ... | Binary files /dev/null and b/Chip-dat/farnell-dat/2025-07-08-13-30-49.png differ |
Chip-dat/farnell-dat/2025-07-08-13-31-01.png
| ... | ... | Binary files /dev/null and b/Chip-dat/farnell-dat/2025-07-08-13-31-01.png differ |
Chip-dat/farnell-dat/RF600-dat/2025-07-08-13-18-52.png
| ... | ... | Binary files /dev/null and b/Chip-dat/farnell-dat/RF600-dat/2025-07-08-13-18-52.png differ |
Chip-dat/farnell-dat/RF600-dat/2025-07-08-13-32-47.png
| ... | ... | Binary files /dev/null and b/Chip-dat/farnell-dat/RF600-dat/2025-07-08-13-32-47.png differ |
Chip-dat/farnell-dat/RF600-dat/RF600-dat.md
| ... | ... | @@ -0,0 +1,18 @@ |
| 1 | + |
|
| 2 | +# RF600-dat |
|
| 3 | + |
|
| 4 | +- [[rf600-DS.pdf]] |
|
| 5 | + |
|
| 6 | +== RF / IR Encoder / Decoder Chipset RF Evaluation Boards, == RF600E RF600D == mark "sa901b" SA901B 2041 |
|
| 7 | + |
|
| 8 | + |
|
| 9 | + |
|
| 10 | + |
|
| 11 | + |
|
| 12 | + |
|
| 13 | +2041 could be the 41st week of 2020. |
|
| 14 | + |
|
| 15 | + |
|
| 16 | +## ref |
|
| 17 | + |
|
| 18 | +- [[RF-LINK-dat]] |
|
| ... | ... | \ No newline at end of file |
Chip-dat/farnell-dat/RF600-dat/rf600-DS.pdf
| ... | ... | Binary files /dev/null and b/Chip-dat/farnell-dat/RF600-dat/rf600-DS.pdf differ |
Chip-dat/farnell-dat/farnell-dat.md
| ... | ... | @@ -0,0 +1,10 @@ |
| 1 | + |
|
| 2 | +# farnell-dat.md |
|
| 3 | + |
|
| 4 | +- [[RF600-dat]] |
|
| 5 | + |
|
| 6 | +- SA-01B |
|
| 7 | + |
|
| 8 | + |
|
| 9 | + |
|
| 10 | + |
|
| ... | ... | \ No newline at end of file |
Tech-dat/Network-dat/RF-dat/RF-LINK-dat/2025-07-08-13-40-47.png
| ... | ... | Binary files /dev/null and b/Tech-dat/Network-dat/RF-dat/RF-LINK-dat/2025-07-08-13-40-47.png differ |
Tech-dat/Network-dat/RF-dat/RF-LINK-dat/RF-LINK-dat.md
| ... | ... | @@ -7,8 +7,9 @@ |
| 7 | 7 | |
| 8 | 8 | - [[RF-Modulation-dat]] |
| 9 | 9 | |
| 10 | -## products |
|
| 10 | +- learning code RF link, rolling code RF link, fixed code RF link, etc. |
|
| 11 | 11 | |
| 12 | +## products |
|
| 12 | 13 | |
| 13 | 14 | - [[NWL1016-dat]] - [[NWL1017-dat]] |
| 14 | 15 | |
| ... | ... | @@ -61,6 +62,8 @@ learning code |
| 61 | 62 | |
| 62 | 63 | fixed (welding code) code |
| 63 | 64 | |
| 65 | +- [[rolling-code-dat]] - [[rolling-code-encoder-dat]] - [[rolling-code-decoder-dat]] |
|
| 66 | + |
|
| 64 | 67 | ## working mode |
| 65 | 68 | |
| 66 | 69 | ### Jog (M4) Single Working Mode Description: |
| ... | ... | @@ -194,6 +197,57 @@ If you're using **common learning-code RF modules**: |
| 194 | 197 | |
| 195 | 198 | - [[EV1527-dat]] |
| 196 | 199 | |
| 200 | +- [[RF600-dat]] |
|
| 201 | + |
|
| 202 | +2264、2262、2260、2240、1527、527、SMC918 |
|
| 203 | + |
|
| 204 | +- clones of the PIC12xxx == [[PIC12-dat]] - [[PIC-dat]] |
|
| 205 | + |
|
| 206 | + |
|
| 207 | +## Copier |
|
| 208 | + |
|
| 209 | + |
|
| 210 | + |
|
| 211 | + |
|
| 212 | +### 1️⃣ Clear Existing Codes (Code Erase) |
|
| 213 | + |
|
| 214 | +> **Purpose:** |
|
| 215 | +> Remove all previously stored codes from the remote. |
|
| 216 | +> **Note:** Only perform this on a new remote. Do **not** clear your original remote unless necessary. |
|
| 217 | + |
|
| 218 | +**Steps:** |
|
| 219 | +1. **Press and hold** the two upper buttons on the remote **simultaneously** (regardless of their symbols). |
|
| 220 | +2. **Keep holding** until the indicator LED flashes rapidly and continuously. |
|
| 221 | +3. **Release** both buttons. |
|
| 222 | + → The remote's memory is now cleared. |
|
| 223 | + |
|
| 224 | +--- |
|
| 225 | + |
|
| 226 | +### 2️⃣ Copy (Pair) Codes from Old Remote to New Remote |
|
| 227 | + |
|
| 228 | +> **Purpose:** |
|
| 229 | +> Clone the code from your original remote to the new remote. |
|
| 230 | + |
|
| 231 | +**Steps:** |
|
| 232 | +1. Hold the **old** and **new** remotes close together. |
|
| 233 | +2. **Press and hold** the same button on both remotes at the same time. |
|
| 234 | +3. Wait until the indicator LED on the new remote flashes rapidly. |
|
| 235 | +4. **Release** both buttons. |
|
| 236 | + → The code is copied successfully. |
|
| 237 | + |
|
| 238 | +**Notes:** |
|
| 239 | +- Repeat the process **for each button** (all four buttons must be copied individually). |
|
| 240 | +- Button symbols may differ between remotes, but the function will be copied as per the original. |
|
| 241 | + |
|
| 242 | +--- |
|
| 243 | + |
|
| 244 | +### ⚠️ Important Reminders |
|
| 245 | + |
|
| 246 | +- Only clear codes on a new remote, not your original one. |
|
| 247 | +- Each button must be paired separately, even if the symbols are different. |
|
| 248 | +- Keep remotes close together during the copying process for best results. |
|
| 249 | + |
|
| 250 | +--- |
|
| 197 | 251 | |
| 198 | 252 | ## code |
| 199 | 253 |
Tech-dat/Network-dat/RF-dat/RF-LINK-dat/rolling-code-dat/rolling-code-dat.md
| ... | ... | @@ -0,0 +1,11 @@ |
| 1 | + |
|
| 2 | +# rolling-code-dat |
|
| 3 | + |
|
| 4 | +- HCS301 |
|
| 5 | +- HCS101 |
|
| 6 | + |
|
| 7 | + |
|
| 8 | +## ref |
|
| 9 | + |
|
| 10 | +- [[RF-link-dat]] |
|
| 11 | + |