sample data
F2 5A 02 E1 80 00 06 52 0 3E A8 3 A6 C8 4F 9A E8 5E 79 B 61 0 1 27
Voltage Parameter Register
02 E1 80
Summing these values gives the voltage parameter register value: 131072 + 57600 + 128 = 188800
Voltage Register Calculation
00 06 52
voltage register value: 0 + 1536 + 82 = 1618
Effective Voltage Calculation
Therefore, the effective voltage is approximately 219.372V.
obselete
Hex Read
F2 5A 02 DC D0 04 C8 20 00 3E 4E 03 7C A6 4E 2B B8 B9 8A BB 61 00 01 DC
seperated: F2 | 5A | 02 DC D0 | 04 C8 20 | 00 3E 4E | 03 7C A6 | 4E 2B B8 | B9 8A BB | 61 | 00 01 | DC
convert to int: 85 90 2 220 208 4 134 64 0 62 78 4 25 218 78 43 184 235 216 59 97 0 0 139
hex | dec / int | |
---|---|---|
start | F2 | 242 |
Check register | 5A | 90 |
Voltage parameter register | 02 DC D0 | 2 220 208 |
Voltage register | 04 C8 20 | 4 134 64 |
Current parameter register | 00 3E 4E | 0 62 78 |
Current register | 03 7C A6 | 3 124 166 |
Power parameter register | 4E 2B B8 | 78 43 184 |
Power register | B9 8A BB | 235 216 59 |
Data updata register | 61 | 97 |
PF register | 00 01 | 0 1 |
CheckSum register | DC | 139 |