MPC1073-test-log-dat.md
P8 P10 Outdoor 32x16 == tested = OK
Run example for our selling 32x16 panel
P10 - 32x16
./examples-api-use/demo -D 0 --led-cols=32 --led-rows=16 --led-multiplexing=8
./examples-api-use/demo -D 0 --led-cols=32 --led-rows=16 --led-multiplexing=3
./examples-api-use/runtext16.ppm -D 0 --led-cols=32 --led-rows=16 --led-multiplexing=8
./examples-api-use/demo -D 0 --led-cols=32 --led-rows=32 --led-multiplexing=1
To chain other panel:
--led-chain=2 to --led-chain=4
Other example will have the same configuration
--led-rows=8 --led-chain=2
32x32
multiplexing =1
./examples-api-use/demo -D 0 --led-cols=32 --led-rows=32 --led-multiplexing=1
P4 64x32 == tested
Tested panel is 64x32 P4-256x128-2121-A1, multiplexing=0
./examples-api-use/demo -D 0 --led-cols=64 --led-rows=32 --led-multiplexing=0
P3/P4 64x64 == tested
Extra Setup Needed
-
Setup P4 jumper to ground, P8 jumper to #E line - MPC1073-multiplexing-dat
-
multiplexing usually 0 or 1, try further options only when you have special board CMD for both P3/P4
commands
./examples-api-use/demo -D 0 --led-cols=64 --led-rows=64 --led-multiplexing=1
128x128 / 256x128 == X
- Not tested yet, should be not supported
more demos
cmd
./demo -D 1 runtext.ppm --led-no-hardware-pulse --led-slowdown-gpio=4 --led-cols=64 --led-rows=32
panel info (obseleted part)
Working Panel | Panel Specification | Command |
---|---|---|
32x16 P8 or P10 | 1/4 | ./demo -D 0 –led-rows=8 –led-chain=2 |
32x32 P6 | 1/8 | |
64x32 P4 | 1/16 | |
64x64 P4 | 1/32 |